A proven core implant systems For Digital implant solution
CORE1 IMPLANT
A proven core implant systems For Digital implant solution
“ What is an Implant? ”
Implants are the most advanced form of treatment to
replace lost teeth by planting
artificial teeth in the position of lost teeth.
It is a prosthetic treatment method that can almost completely replace teeth
by placing titanium-based implants
(fixture, a screw-like structure that is planted in the gum bone)
on the lost teeth through surgery and creating prosthesis similar to
natural teeth after a certain period of time after surgery.
Target for implant treatment
Those who have lost teeth due to various reasons such as
periodontal disease, tooth decay or trauma
Those who feel aesthetic discomfort due to tooth loss
Those who experience discomfort while using dentures
Those whose digestive system is weakened due to loss of
teeth and unable to chew food properly
Implant procedure
Step1 Examination and diagnosis
Step2 Implant surgery
Step3 Confirmation of osseointegration and abutment
Step4 Completion of implant
Step5 Maintenance
Precautions after surgery
Hemostasis Keep the gauze on for 2 hours after surgery.
Even if you have a runny nose or nosebleed, wipe your nose
without blowing your nose.
Disinfection
/ brushingAvoid vigorous oral irrigations for 24 hours on the
first day after surgery.
Do not brush the surgical area and brush the rest of the teeth.
Swelling Apply ice for 2 days after surgery.
Repeat 1 minute of ice pack and 1 minute of rest.
Medication Please take the medicine as prescribed.
It serves to prevent inflammation.
(Please do not take medicine.)
Food intake For 5 days after surgery, please eat liquid food
(porridge, etc.), and do not eat hot food.
It may cause surgical failure.
ontraindications Do not drink or smoke. (at least for 2-3 weeks)
Avoid saunas, jjimjilbangs, baths, and sweaty
exercises for about 2 weeks. (Taking a shower is fine.)
The alpha and omega of digital implants Implant System
Implant with strong initial fixation
and good osseointegration
S.L.AIdeal SLA validated for over 10 years
(Sandblast Large grit Acid etch)
Rapid osseointegration induction with
implant surface treatment technology
6 weeksProsthesis can be inserted 6 weeks
after implant placement
Digital Care
SolutionUsing CT 3D image data and Cybermed's own
digital system, a pre-treatment plan is established
and faster, more accurate, and safer
treatment is possible through simulated surgery
If you want accurate and safe procedures
Cybermed's Digital Care Solution
1Digital diagnostics
2Digital plan
3Digital production
4implant surgery
The implant material uses TI CPA – Hard,
which has higher strength than pure titanium alloy.
Titanium Gr4-Hard (modified Ti G4)
· It is biologically safe without causing implant
surface corrosion and decomposition.
· It can withstand the masticatory force in the
oral cavity and has a similar modulus of elasticity to
the surrounding bone tissue.
· Sufficient strength and precision machining in
㎛ units are possible.
Fig.8 – Curves from tensile tests of cp
Ti and Ti G5
The implant surface is S.L.A,
realizing the same level as Straumann's
SEM measurements
1~3㎛ uniform micro-pit is realized,
and it is on the same level as S company
BIC measurement
Top
Middle
Bottom
As a result of the 12-week tissue test, the average
BIC of 95% or more was confirmed.
EDS measurement
* No other substances of titanium were found on the implant surface.
Surface roughness
Realization of Ra 2.0~2.5㎛ roughness
Cybermed Co., Ltd., which has developed world-class dental software,
is the world's No. 1 company in dental CBCT imaging software,
and has been trusted by many clinical experts and patients with
its technology accumulated
over 20 years. Get surgery with a healthy smile and safe
implants with reliable and differentiated digital implants.
01Platform Switching
Increases soft tissue volume around connection
Superior esthetics
02SLA Surface
Application of SLA surface with excellent bone reaction performance
The best morphology and roughness's SLA Surface.
x2000
x4000
03Internal Taper Connection
Rigid connection for prostheiss stability
Stress dispersal effect
04Compact Thread
Superior primary stability
Maximizes bone to thread contact
05Open Thread
Minimizes resistance during placement
Prevents bone loss
06Sharp Double Thread
Powerful self-threading effect to achieve superior placement results
Maximizes preservation of existing bone and space for new bone to grow
07Cutting Edge
3-blade cutting edge ensures a self-centering insertion
Excellent initial thread engagement for optimal anchorage
Smooth Implant Placement. High Primary Stability
Self Threading Effect
Sharp Thread maximizes preservation of the existing bone and secures anchorage
Double Thread minimizes implant placement time
Plasma Surface Treatment, Clean Implant!
Increases hydrophilicity and accelerates synostosis by attracting blood and protein to the area
Accelerates patient recovery time, as Plasma doesn't have any known side effects to human immune system.
Suppresses bacterias in oral cavity, therefore lengthening implant's lifespan